The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This chapter describes how to install the 1552 access point and contains the following sections:
When you are unpacking the access point, do not remove the foam blocks attached to the antenna connectors. The foam protects the antenna connectors during installation.
To unpack the access point, follow these steps:
Step 1 Open the shipping container and carefully remove the contents.
Step 2 Return all packing materials to the shipping container, and save it.
Step 3 Ensure that all items listed in “Package Contents” are included in the shipment. If any item is damaged or missing, notify your authorized Cisco sales representative.
The typical access point package contains the following items:
The tools and hardware used to install the 1552 access point are described in:
The optional tools and hardware that can be obtained from Cisco are:
– 40-ft (12.2-m) power cord with North American plug (AIR-CORD-R3P-40NA=) for light pole installations in the US and Canada
– AC power cord, 40 ft (12.2 m) with European unterminated end (AIR-CORD-R3P-40UE=) for light pole installations outside of the US and Canada
– 4-ft (1.2-m) streetlight power tap adapter (AIR-PWR-ST-LT-R3P=) for light pole installations in the US and Canada
Tools and materials that are user-supplied are:
To install the access point on a vertical or horizontal metal, wood, or fiberglass pole, you need the following additional hardware and tools:
To install the access point on a cable strand, you need the following additional parts:
– Four hex bolts (M8, 0x16mmL)
– Four M8 split lock washers (0.14 8mmoD, 2mmT)
– Four M8 flat washers (16.0mmOD, 1.6mmT)
– Two carriage bolt fasteners (5/16-18 x 1.25 in.)
– Six hex nuts, serrated flange (5/16-18)
– Four carriage bolts (5/16 x 5/8LG)
– Strand mounting brackets—1 left bracket, 1 right bracket, 2 adjustable brackets
Translated versions of all safety warnings are available in the safety warning document that shipped with your access point or on Cisco.com. To browse to the document on Cisco.com, refer to Appendix A, “Translated Safety Warnings” for instructions.
Warning IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071
SAVE THESE INSTRUCTIONS
Warning This equipment is to be installed by trained and qualified personnel, as per these installation instructions. The installer is responsible for obtaining any required local or national safety inspections of the structural integrity of the installation by the local authority/inspection department.
Warning Do not operate the unit near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. Statement 364
Warning The cables specified in this installation guide that are used with the specified liquid-tight adapters provide protection against ingress of moisture for a Type 4/IP67 classified enclosure. If substitute cable are used, the installer must ensure that the size (OD) of the cable meets the acceptable range allowed by the liquid-type adaptor.
Warning This equipment must be externally grounded using a customer-supplied ground wire before power is applied. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 366
Warning Read the installation instructions before connecting the system to the power source. Statement 1004
Warning Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040
Follow the guidelines in this section to ensure proper operation and safe use of the access point.
The FCC, with its action in ET Docket 96-8, has adopted a safety standard for human exposure to RF electromagnetic energy emitted by FCC-certified equipment. When used with approved Cisco Aironet antennas, Cisco Aironet products meet the uncontrolled environmental limits found in OET-65 and ANSI C95.1, 1991. Proper operation of this radio device according to the instructions in this publication results in user exposure substantially below the FCC recommended limits.
Warning In order to comply with FCC radio frequency (RF) exposure limits, antennas with less than 8 dBi gain should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons and 20 inches (50 cm) for antennas with up to 13 dBi gain. Statement 332
Warning The AC power supply has double pole/neutral fusing. Statement 188
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001
Warning Class 1 laser product. Statement 1008
Warning There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Statement 1015
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
Warning Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV) requirements in IEC 60950 based safety standards. Statement 1033
Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046.
Warning Do not locate the antenna near overhead power lines or other electric light or power circuits, or where it can come into contact with such circuits. When installing the antenna, take extreme care not to come into contact with such circuits, because they may cause serious injury or death. For proper installation and grounding of the antenna, please refer to national and local codes (for example, U.S.:NFPA 70, National Electrical Code, Article 810, Canada: Canadian Electrical Code, Section 54). Statement 1052
For additional important safety instructions for AC power cords, refer to the AC Power Cords for Cisco Aironet 1550 Series Outdoor Mesh Access Points document that shipped with your AC power cords.
For safety and to achieve a good installation, please read and follow these safety precautions:
– Do not work on a wet or windy day.
– Do dress properly—shoes with rubber soles and heels, rubber gloves, long sleeved shirt or jacket.
If an accident should occur, call for qualified emergency help immediately.
The radios on outdoor units (bridges) have higher transmit power levels than radios on indoor units (access points). When you test high-power radios in a link, you must avoid exceeding the maximum receive input level for the receiver. At levels above the normal operating range, packet error rate (PER) performance is degraded. At even higher levels, the receiver can be permanently damaged. To avoid receiver damage and PER degradation, you can use one of the following techniques:
Note These distances assume free space path loss and are conservative estimates. Required separation distances for damage and performance degradation levels in actual deployments are less if conditions are not non-line-of-sight.
For a radiated test bed, the following equation describes the relationships among transmit power, antenna gain, attenuation, and receiver sensitivity:
For a conducted test bed, the following equation describes the relationships among transmit power, antenna gain, and receiver sensitivity:
Because the access point is a radio device, it is susceptible to common causes of interference that can reduce throughput and range. Follow these basic guidelines to ensure the best possible performance:
Note To calculate path loss and to determine how far apart to install access points, consult an RF planning expert.
Every network application is a unique installation. Before installing multiple access points, you should perform a site survey to determine the optimum use of networking components and to maximize range, coverage, and network performance.
Consider the following operating and environmental conditions when performing a site survey:
Before you begin the installation process:
The access point is designed to be installed in an outdoor environment, such as the exterior roof overhang of a tall building or a streetlight pole. Carefully review the following figures to become familiar with the system components, connectors, indicators, cables, system interconnection, and grounding:
Note The illustrations in this document show all available connections for the access point. Unused connections are capped with a connector plug to ensure the watertight integrity of the access point, except for the AC power entry connector on the 1552E access point. Liquid-tight adapters are provided for connector openings, which can be installed before or after deploying the access point.
When not using the AC input connector to power the 1552E (for example when powering using the Cisco power injector), it is important to cover the AC power entry connector. The correct cap is Remke part number 75-0086 (http://www.remke.com/).
Figure 2-1 Components in a Typical Access Point Installation
|
|
||
|
Shielded outdoor-rated Ethernet |
|
AC power cord2 |
|
|
Power injector3 |
|
|
|
||
|
|
Note The 1552 access point was designed with consideration for resistance to effects of lightning effects on the access point electronics. The 1552 access point employs lightning arrestor circuitry on the Ethernet and power ports. On the input Ethernet port, Gas Discharge Tubes (GDT) are used for the Power Entry Module (PEM) to mitigate lightning effect. On the AC power, GDTs are also used along with fuses to mitigate high-current condition. For the DC power, a fuse is used to mitigate high current condition.
While not a common practice, the user may want to consider using lightning protection at the antenna ports for added protection. To meet EN/IEC60950-22 (Clause 4.2) requirements, the installer must ensure that additional protection is provided external to this equipment to reduce transient surges from Overvoltage IV to Overvoltage Category II at the AC power input of the access point. The over-voltage and fault-current protection components used to achieve this protection must comply with the IEC 61643 series of standards. To meet CAN/CSA-C22.2 No. 60950-22-07/UL60950-22 requirements, the installer may use alternative components to provide this additional protection. Those components may comply with ANSI/IEEE C62.11, CSA Certification Notice No. 516, CSA C22.2 No. 1, or UL 1449. Suitability of the components for the application must be determined for the intended installation. (For example, some devices are suitable for installation on the load side of the service entrance only, and some are suitable for use with cord-connected equipment only.)
Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074
Figure 2-2 Pole Mount Installation
|
|
Cisco Aironet Dual-Band Omnidirectional Antennas. The dual-band antenna covers both the 2.4 GHz and 5 GHz bands. |
|
|
Pole (wood, metal, or fiberglass) |
|
|
|
|
Figure 2-3 Cable Strand Mounting Example - Shown on a 1552 Model AIR-CAP1552C-x-K9
|
|
Low-profile dual-band (2.4 GHz and 5 GHz) 3-element array antenna unit |
|
|
|
F-connector adapter for the POC cable (only on model AIR-CAP1552C-x-K9) |
|
|
|
Figure 2-4 Streetlight Power Tap Adapter Installation
|
|
||
|
|
You need to open the access point hinged cover when you are installing fiber-optic SFP module and fiber cable take-up reels.
To open the access point hinged cover, follow these steps:
Step 1 Use 0.5-in (13-mm) box-end wrench or socket set to unscrew and remove the four bolts on the front cover of the unit. Only unscrew the hinge bolts about 2 turns until they are easily turned by hand, do not remove the bolts on the hinge (Figure 2-5).
Step 2 The cover is hinged on the bottom. Carefully open the cover and remove the cover.
Note If the cover does not open easily, carefully loosen the hinge bolts again.
Figure 2-5 Access Point Front View of Hinged Cover
|
|
To close the access point cover, follow these steps:
Step 1 When closing the access point cover, be careful not to pinch internal wires.
Step 2 Carefully position the cover flush with all sides of the access point, then slowly hand-tighten each bolt.
Step 3 When all bolts are hand-tightened, use a 13-mm closed-end wrench or socket to partially tighten the bolts in the tightening sequence shown in Figure 2-6. Tighten each bolt to 3 to 4 ft lbs (0.34 to 0.45 Nm).
Step 4 Repeat Step 3 using the same tightening sequence to fully tighten each bolt to 6 to 7 ft lbs
(0.68 to 0.79 Nm).
Figure 2-6 Hinged Cover Bolt Tightening Sequence
Tighten the bolts in the numeric order shown, starting with 1. |
This section provides instructions for installing your access points. Personnel installing the access point must understand wireless access points and bridging techniques and grounding methods.
There are two optional installation kits:
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074
Refer to these sections for installation details:
– Cable Strand Mounting the 1552C or 1552CU Access Point
– Mounting the 1552C or 1552CU Access Point on a Pole/Wall
– Mounting the 1552C or 1552CU Access Point Facing Up in a Vault Application
When mounting an access point on a horizontal or vertical surface, you must ensure that the access point is oriented with the LED indicators pointing down (see Figure 2-2, Figure 2-3, and Figure 2-4). This positioning allows the LEDs to be visible to someone on the ground below the access point.
You must also ensure the access point is mounted with the hinged access cover facing out.
Note Omnidirectional antennas are vertically polarized and should be mounted vertically with the antennas facing down.
The optional pole mount kit contains a mounting bracket for wall mounting. You can use the mounting bracket as a template to mark the positions of the mounting holes for your installation. You then install the mounting plate, and attach the access point when you are ready. Table 2-1 lists the material that you will need to provide in addition to the pole mount kit.
To mount the access point on a vertical wall, follow these instructions:
Step 1 Use the mounting bracket as a template to mark four screw hole locations on your mounting surface. See Figure 2-7 for the mounting bracket screw hole locations. You can optionally use the individual mounting holes or the mounting slots.
Figure 2-7 Mounting Bracket for Wall Mounting
|
|
||
|
|
Step 2 Use four customer-supplied screws and optional screw anchors to attach the mounting plate to the mounting surface.
Note If necessary, use suitable screw anchors and an exterior-grade plywood backboard to mount the access point to stucco, cement, or drywall.
Step 3 Continue with Installing 1552E, 1552EU, or 1552I in the Mounting Bracket or Installing 1552C or 1552CU in the Mounting Bracket, depending on what you purchased.
When installing an access point on a vertical pole, mast, or a streetlight pole, you should use the optional Cisco pole mount kit. The kit supports metal, wood, or fiberglass poles from 2 to 16 inches in diameter.
When installing an access point on a pole, mast, or a streetlight, you should use the optional Cisco pole mount kit. The kit supports metal, wood, or fiberglass poles from 2 to 16 inches in diameter.
The pole mount kit contains several parts that you must assemble prior to mounting on a pole. First you need to assemble two strap brackets on the pole clamp bracket that are positioned for the pole diameter you are using to mount the access point. Figure 2-8 illustrates the pole diameter indicators and bolt holes on the pole clamp bracket.
Figure 2-8 Pole Clamp Bracket Adjustment Hole Locations
To assemble the pole clamp bracket, follow these steps:
Step 1 Position the strap brackets on the pole clamp bracket for the pole diameter you are using and secure each strap bracket with two M8 x16 bolts (with lock washers) (see Figure 2-9). Tighten the bolts to 13 to 15 ft lbs (17.6 to 20.3 Nm).
Figure 2-9 Assembled Pole Clamp Bracket and Strap Brackets
Strap bracket (shown positioned for 11 to 16 inch diameter pole) |
|||
Step 2 Screw the M8 nut onto the pole clamp bracket support bolt, and tighten just enough to prevent the bolt from falling off.
Step 3 Go to the “Mounting Bracket Assembly on a Pole” section.
The access point can be installed where power is available, without the need for a wired LAN connection. The access point uses intelligent wireless routing that is based on the Adaptive Wireless Path Protocol (AWPP). AWPP enables a remote access point to dynamically optimize the best route to the wired LAN network using another access point.
The 1552 access point uses the 5-GHz radio for the Mesh backhaul and connections. The 2.4-GHz radio is used for local wireless client access.
To mount your access point on a vertical pole or streetlight pole, you need to install two metal bands around the pole to support the access point. This process requires extra tools and material not provided in the pole mount kit (see Table 2-2 ).
|
|
|
---|---|---|
To mount the access point onto a vertical pole or streetlight pole, follow these steps:
Step 1 Select a mounting location on the pole to mount the access point. You can attach the access point to any pole from 2 to 16 inch (5.1 to 40.6 cm) in diameter.
Note If you will be using a streetlight power tap adapter, position the access point within 3 ft (1 m) of the outdoor light control.
Step 2 For poles larger than 3.5 inch (8.9 cm), mount the pole clamp bracket assembly to a pole (see Figure 2-10) using two metal straps. Following the instructions provided with the banding strap tool (BAND IT) (AIR-BAND-INST-TL=), loop each metal strap twice through the slots on the strap bracket.
Figure 2-10 Clamp Bracket Assembly Mounted on Poles Larger than 3.5 inch (8.9 cm)
|
|
||
|
|
Step 3 For pole diameters of 3.5 inch (8.9 cm) or less, mount the pole clamp bracket assembly to a pole using two metal straps looped through the space between the pole clamp bracket and the strap brackets (see Figure 2-11) to provide maximum holding strength for extreme environments. Following the instructions provided with the banding strap tool (BAND IT) (AIR-BAND-INST-TL=), loop each metal strap twice.
Figure 2-11 Metal Strap Open Space for 3.5 inch (8.9 cm) and Smaller Poles
|
Step 4 Position the pole clamp bracket on the pole as needed before tightening the metal bands.
Note When the metal bands are tightened to the full tension, the pole clamp bracket cannot be adjusted unless the metal bands are cut or disassembled.
Step 5 Tighten the metal bands using the banding strap tool (BAND IT) (Cisco AIR-BAND-INST-TL=) by following the operating instructions in the box with the tool. Ensure that the metal bands are as tight as possible.
Step 6 Place the mounting bracket onto the pole clamp bracket support bolt (see Figure 2-12).
Step 7 For vertical poles, position the mounting bracket as shown in Figure 2-12. For horizontal streetlight poles, rotate the mounting bracket 90o from the position shown in Figure 2-12.
Step 8 Install four M8 x16 bolts (with flat and lock washers) into the bolt holes.
Figure 2-12 Screw Hole Locations on the Mounting Bracket and Pole Clamp Bracket Assembly
|
|
||
|
|
Step 9 Hand-tighten the bolts and the nut (do not overtighten).
Step 10 Adjust the top edge of the mounting bracket until it is horizontal and tighten the bolts and the flange nut (see Figure 2-12) to 13 to 15 ft lbs (17.6 to 20.3 Nm).
Note The mounting bracket can be adjusted up to 45o to compensate for tilted horizontal streetlight poles.
Step 11 Continue with Installing 1552E, 1552EU, or 1552I in the Mounting Bracket or Installing 1552C or 1552CU in the Mounting Bracket, depending on what you purchased.
Step 1 Screw a M8 x16 bolt (without a flat or lock washer) in the top support bolt hole on each side of the access point (see Figure 2-13 or Figure 2-14, depending on what you purchased). These bolts are supplied with pole mount kit. Do not screw the bolt all the way in. Leave a gap of approximately 0.25 inch (0.635 cm).
Figure 2-13 Location of Access Point Top Support Bolt Hole on 1552E/1552EU
|
|
||
|
|
Figure 2-14 Location of Access Point Top Support Bolt Hole on 1552I
|
|
||
|
|
Step 2 Position the two bolts on the access point into the appropriate quick mount notches on each side of the mounting bracket (see Figure 2-15 for the 1552E/1552EU model or Figure 2-16 for the 1552I model).
Note For the 1552E/1552EU model, ensure that the hinged door is facing out. The 1552E/1552EU access point should be positioned with the LEDs on the bottom to allow viewing from the ground and with the hinged cover facing out.
Note For the 1552I model, ensure that the access point is positioned with the LEDs facing inward toward the mounting bracket.
Figure 2-15 Access Point 1552E/1552EU Hanging in Mounting Bracket
Figure 2-16 Access Point 1552I Hanging in Mounting Bracket
Step 3 Screw a M8 x16 bolt (with flat and lock washers) into the second bolt hole on each side of the access point (see Figure 2-15).
Step 4 Depending on what you purchased, ensure that the front of the 1552E/EU access point is vertical, or that the 1552I access point is horizontal, and tighten the four bolts to 13 to 15 ft lbs
(17.6 to 20.3 Nm).
Step 5 For the 1552E/EU model continue with Installing Antennas. For the 1552I model continue with Grounding the Access Point and Powering the Access Point.
There are three different options for mounting the 1552C or 1552CU access point:
When mounting the access point on a cable strand, you must use the optional strand mount kit. The kit contains several parts that you should assemble before mounting on a cable strand. To install the access point to a cable strand, you need to perform these operations:
Note The access point must be installed on a cable strand by a professional cable installer.
Note The 1552C and 1552CU access points can be installed using the pole mount kit in special circumstances. Refer to “Mounting the 1552C or 1552CU Access Point on a Pole/Wall” section or “Mounting the 1552C or 1552CU Access Point Facing Up in a Vault Application” section for installation instructions.
To mount the access point, follow these steps:
Step 1 Assemble the cable clamps to the clamp bracket on both cable brackets (Figure 2-17). You should only hand-tighten the nuts sufficiently to prevent them from falling off.
Figure 2-17 Assemble Cable Brackets
Step 2 Secure each strap bracket with two M8 x16 bolts (with lock washers) on each side of the access point with the antennas facing down. (Figure 2-18). Only hand-tighten the bolts to 13 to 15 ft lbs (17.6 to 20.3 Nm).
Figure 2-18 Attach Strap Brackets to Access Point
M8 x16 bolts with lock washers (supplied with cable mount kit) |
|||
Antenna unit assembly (shown with the Low Profile Dual-Band 2.4/5 GHz Omni Antenna Array) |
|||
Step 3 Place the clamp bracket on the strand support cable (see Figure 2-19). On each cable support bolt, ensure that one cable clamp is placed on each side of the support cable. Tighten the two M8 flange nuts to 13 to 15 in. lbs (17.6 to 20.3 Nm). Ensure the cable is mounted to the bottom side of the access point.
Figure 2-19 Attach the Cable Strand to the Cable Mount Brackets
Antenna unit assembly (shown with the Low Profile Dual-Band 2.4/5 GHz Omni Antenna Array) |
|||
F-Connector Adapter (for Cable Modem models only); sometimes referred to as a “stringer” |
|||
Step 4 The assembled cable mounting kit is shown from the top view of the access point (Figure 2-20).
Figure 2-20 Clamp Brackets Attached to Cable Strand-Top View of Access Point
Note The strand support cable might have to be pulled away from the fiber or cable bundle. Be sure to resecure the cable as necessary.
Note The strand support cable and the mounting hardware provide grounding for the access point.
Step 5 For the 1552CU access point, continue with Installing Antennas. For the 1552C access point, continue with Grounding the Access Point and Powering the Access Point.
The 1552C or 1552CU access point can be mounted on a wall, pole, or a below-ground vault location, using the pole mount kit. You can use the mounting bracket as a template to mark the positions of the mounting holes for your installation. You then install the mounting plate, attach the grounding lug, and attach the access point when you are ready.
To mount the 1552C or 1552CU access point on a vertical wall, follow these instructions:
Tip When installing the 1552C or 1552CU access point using the pole mount kit, the grounding lug and cable must be attached to the access point before attaching the access point to the mounting bracket.
Tip When installing the 1552C or 1552CU access point in this configuration, you can use only one hole in the grounding block (see Figure 2-21).
Step 6 Attach the grounding lug and cable to the access point. Refer to “Grounding the Access Point” section.
Figure 2-21 Attaching Grounding Lug to Grounding Point
|
|
||
|
|
Step 7 Screw a M8 x16 bolt in the top support bolt hole on each side the access point (see Figure 2-22). Do not screw the bolt all the way in; leave approximately a 0.25 inch (0.635 cm) space.
Figure 2-22 Position of 1552C or 1552CU Access Point in Pole Mount Bracket
|
|
||
|
|
Step 8 Position the two bolts on the access point into the appropriate quick mount notches on each side of the mounting bracket (see Figure 2-22). Ensure that the hinged door is facing out.
Step 9 Screw a M8 x16 bolt (with flat and lock washers) into the second bolt hole on each side of the access point.
Step 10 Ensure that the front of the access point is vertical, and tighten the four bolts to 13 to 15 ft lbs
(17.6 to 20.3 Nm).
Step 11 For the 1552CU access point, continue with Installing Antennas. For the 1552C access point, continue with Connecting a Cable POC Power to the Access Point.
To mount the 1552C or 1552CU access point on a horizontal surface in a below-ground vault location, follow these instructions:
Step 1 Use the mounting bracket as a template to mark four screw hole locations on your mounting surface. See Figure 2-23 for the mounting bracket screw hole locations. You can optionally use the individual mounting holes or the mounting slots.
Figure 2-23 Mounting Bracket Position for Vault Mounting
|
|
||
|
|
Step 2 Use four customer-supplied screws and optional screw anchors to attach the mounting plate to the mounting surface.
Note If necessary, use suitable screw anchors and an exterior-grade plywood backboard to mount the access point to the base.
Tip When installing the 1552C or 1552CU access point using the pole mount kit, the grounding lug and cable must be attached to the access point before attaching the access point to the mounting bracket.
Step 3 Attach the grounding lug and cable to the access point. Refer to “Grounding the Access Point” section. See Figure 2-24.
Figure 2-24 Attaching Grounding Lug to Grounding Point
|
Phillips head M4 x10mm screws (supplied with pole mount kit) |
|
Step 4 Screw a M8 x16 bolt in the top support bolt hole on each side the access point (see Figure 2-22). Do not screw the bolt all the way in; leave approximately a 0.25 inch (0.635 cm) space.
Figure 2-25 1552C Access Point Facing Up in Vault Location
|
|
||
|
|
Step 5 Position the two bolts on the access point into the quick mount notches on each side of the mounting bracket (see Figure 2-23). Ensure that the hinged door is facing out.
Step 6 Screw a M8 x16 bolt (with flat and lock washers) into the second bolt hole on each side of the access point.
Step 7 Ensure that the front of the access point is vertical, and tighten the four bolts to 13 to 15 ft lbs
(17.6 to 20.3 Nm).
Step 8 For the 1552CU access point, continue with Installing Antennas. For the 1552C access point, continue with Powering the Access Point.
Table 2-3 shows the antennas supported by the 1552 access point and provides required quantities for each model.
|
|
|
|
|
---|---|---|---|---|
For installation instructions and detailed information on these antennas, refer to the appropriate document located at:
http://www.cisco.com/en/US/products/hw/wireless/ps469/prod_installation_guides_list.html
Follow all safety precautions when installing the antennas. For information on safety, refer to “Safety Precautions” section.
The access point antenna N-type connectors are located on the bottom of model AIR-CAP1552E-x-K9 and on both the top and bottom of the AIR-CAP1552EU-x-K9 and the AIR-CAP1552CU-x-K9. The N-type connectors support variety of the Cisco Aironet antennas. For detailed information on these antennas, refer to Antenna Configurations. Figure 2-26 and Figure 2-27 shows the antenna port locations viewed from the RF cover side.
Figure 2-26 Antenna Port Locations - Model AIR-CAP1552E-x-K9
|
|
||
|
|
||
|
|
Figure 2-27 Antenna Port Locations - Models AIR-CAP1552CU-x-K9 and AIR-CAP1552EU-x-K9
|
|
||
|
|
||
|
|
Two mounting configurations are available, the cable strand mount and the pole mount (refer to “Mounting the Access Point” section.)
Using an optional antenna mounting bracket kit, the directional antennas AIR-ANT2413P2M-N and AIR-ANT5114P2M-N can be mounted directly on an access point in a strand mount or pole mount environment. The antenna bracket kit contains four bracket sections and fasteners that you can assemble in multiple configurations to position and aim the directional antenna in a range of positions. For more information on mounting the antenna with the optional mounting bracket, refer to Installing Directional-Antenna Mounting Kits on Cisco 1550 Series Outdoor Mesh Access Points.
Figure 2-28 through Figure 2-31 show the antenna mounting options supported by the various 1552 access point models.
Figure 2-28 shows the integrated low-profile dual-band (2.4 GHz and 5 GHz) 3-element array antenna built-in only on models AIR-CAP1552I-x-K9 and AIR-CAP1552C-x-K9.
Figure 2-28 AIR-CAP1552C-x-K9 and AIR-CAP1552I-x-K9
The AIR-CAP1552E-x-K9 model must always be operated with the three external antennas attached, as shown in Figure 2-29.
|
|
The AIR-CAP1552EU-x-K9 model can be operated in either of the configurations shown below. In addition, it can be operated with one directional antenna installed for one frequency band and three omnidirectional “stick” antennas installed for the other frequency band.
Figure 2-30 AIR-CAP1552EU-x-K9
|
|
|||
|
|
The AIR-CAP1552CU-x-K9 model can be operated with the same configurations as the AIR-CAP1552EU-x-K9 model on a pole mount configuration, as shown in Figure 2-30. In addition, when installed in a cable strand mount configuration, the AIR-CAP1552CU-x-K9 model can be operated with configuration shown in Figure 2-31.
Figure 2-31 AIR-CAP1552CU-x-K9
|
|
Overvoltage transients can be created through lightning static discharges, switch processes, direct contact with power lines, or through earth currents. The Cisco Aironet AIR-ACC245LA-N Lightning Arrestor limits the amplitude and duration of disturbing interference voltages and improves the overvoltage resistance of in-line equipment, systems, and components. A lightning arrestor installed according to these mounting instructions balances the voltage potential, thus preventing inductive interference to parallel signal lines within the protected system.
Cisco recommends that you bulkhead mount the lightning arrestor so it can be installed as a wall-feed through on the wall of the protected space.
The importance of obtaining a good ground and bonding connection cannot be overstressed. Consider these points when grounding the lightning arrestor:
This lightning arrestor is designed to be installed between the antenna cable that is attached to an outdoor antenna and the Cisco Aironet wireless device. You can install the lightning arrestor either indoors or outdoors. It can be connected directly to a wireless device having an external N connector. It can also be mounted inline or as a feed-through. Feed-through installations require 5/8 in. (16 mm) hole to accommodate the lightning arrestor. See Figure 1.
Note This lightning arrestor is part of a lightning arrestor kit. The kit contains a lightning arrestor, a grounding lug, and this instruction sheet.
Note When you install the lightning arrestor, follow the regulations or best practices applicable to lightning protection installation in your local area.
If you install the lightning arrestor outdoors, use the supplied ground lug and a heavy wire (#6 solid copper) to connect it to a good earth ground, such as a ground rod. The connection should be as short as possible.
If you install the lightning arrestor indoors, place the wireless LAN device near a good source of ground, such as structural steel or the ground on an electrical panel. Ground the lightning arrestor by using a heavy wire (#6 solid copper) and connect the ground wire to a good ground on the structural steel or electrical panel. The connection should be as short as possible.
Figure 32 Lightning Arrestor Details
|
|
||
|
|
||
|
Coaxial cable loses efficiency as the frequency increases, resulting in signal loss. The cable should be kept as short as possible because cable length also determines the amount of signal loss (the longer the run, the greater the loss).
Cisco recommends a high-quality, low-loss cable for use with the lightning arrestor.
Warning Do not locate the antenna near overhead power lines or other electric light or power circuits, or where it can come into contact with such circuits. When installing the antenna, take extreme care not to come into contact with such circuits, as they may cause serious injury or death. For proper installation and grounding of the antenna, please refer to national and local codes (e.g. U.S.: NFPA 70, National Electrical Code, Article 810, Canada: Canadian Electrical Code, Section 54). Statement 280
For your safety, read and follow these safety precautions.
1. Before you install an antenna, contact your Cisco account representative to explain which mounting method to use for the size and type of antenna that you are about to install.
2. Select your installation site with safety, as well as performance, in mind. Remember that electric power lines and phone lines look alike. For your safety, assume that any overhead line can kill you.
3. Contact your electric power company. Tell them your plans and ask them to come look at your proposed installation.
4. Plan your installation carefully and completely before you begin. Each person involved in an installation should be assigned to a specific task and should know what to do and when to do it. One person should be in charge of the operation to issue instructions and watch for signs of trouble.
5. When installing your antenna, follow these guidelines:
– Do not work on a wet or windy day.
– Do dress properly—wear shoes with rubber soles and heels, rubber gloves, and a long-sleeved shirt or jacket.
6. If the assembly starts to drop, move away from it and let it fall. Because the antenna, mast, cable, and metal guy wires are all excellent conductors of electrical current, even the slightest touch of any of these parts to a power line completes an electrical path through the antenna and the installer.
7. If any part of the antenna system should come in contact with a power line, do not touch it or try to remove it yourself. Call your local power company to have it removed safely.
8. If an accident should occur with the power lines, call for qualified emergency help immediately.
The access point must be grounded before connecting power.
Warning This equipment must be externally grounded using a customer-supplied ground wire before power is applied. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 366
Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074
Note When the access point is cable strand mounted, the strand support cable and the mounting hardware provide grounding for the access point.
In all outdoor installations and when powering the access point with AC power, you must follow these instructions to properly ground the case:
Step 1 If using insulated 6-AWG copper ground wire, strip the insulation as required for the grounding lug.
Step 2 Use the appropriate crimping tool to crimp the bare 6-AWG copper ground wire to the supplied grounding lug (Panduit PLCD6-10A-L).
Note The grounding lug and hardware used must comply with local and national electrical codes.
Step 3 Open the electrical joint compound (supplied), and apply a liberal amount over the metal surface where the ground strap screw holes are located (see Figure 2-13).
Step 4 Connect the grounding lug to the access point grounding screw holes (see Figure 2-13) using the supplied two Phillips head screws (M4 x10 mm) with lock washers. Tighten the grounding screw to
22 to 24 in. lbs (2.49 to 2.71 Nm).
Step 5 If necessary, strip the other end of the ground wire, and connect it to a reliable earth ground such as a grounding rod (see Figure 2-2), an appropriate grounding point on a metal streetlight pole that is grounded (see Figure 2-39), or a grounded cable on a cable strand.
The fiber-optic kit (AIR-1520-FIB-REEL=) enables the access point to support fiber-optic network connections. The kit contains these parts:
Note Fiber backhaul is only possible on the 1552E and 1552EU access points.
Warning Class 1 laser product. Statement 1008
Note You need a customer-supplied outdoor-rated fiber-optic cable with an LC connector. The cable diameter must be 0.20 to 0.35 in. (0.52 to 0.89 cm) in diameter.
To connect a fiber-optic cable to the access point, follow these steps:
Step 1 Ensure that all power sources have been disconnected from the access point.
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
Note If your access point contains a backup battery pack, you must depress the reset button for
10 seconds or more (see the “Disabling Backup Battery Power” section).
Step 2 Open the hinged cover (see the “Opening the Access Point Hinged Cover” section for instructions).
Step 3 Place the two large reels with the small reels on top as shown in Figure 2-33.
Step 4 Align the screw holes in the large and small reels, and insert four attachment screws in each of the reel pairs. Tighten the screws to 3 to 4 in. lbs (0.34 to 0.45 Nm).
Step 5 Remove the plug from the end of the SFP module, and insert the module into the SFP receptacle (see Figure 2-33).
Figure 2-33 Fiber-Optic Cable Components
|
|
||
|
|
||
|
|
Step 6 Loosen the round end of the liquid-tight connector by turning counterclockwise, but do not remove (see Figure 2-34).
Figure 2-34 Liquid -Tight Adapter
|
|
Step 7 Carefully screw the threaded end of the adapter into the access point and hand-tighten.
Step 8 Use an adjustable wrench, the 22 mm socket, or the Sealcon S-2200-WR wrench to tighten the threaded end of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 9 Carefully remove approximately 1 to 2 ft (30.5 cm) of the external jacket from the fiber-optic cable, exposing the inner strand.
Step 10 Carefully insert the fiber-optic LC cable connector into the rounded end of the liquid-tight adapter (see Figure 2-34), and push through the adapter.
Step 11 Wrap excess fiber-optic cable around the take-up reels in a figure eight (8) pattern.
Step 12 Insert the fiber-optic LC cable connector into the SFP module.
Step 13 Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs
(3.66 to 4.34 Nm).
Step 14 Close the hinged cover (see the “Closing the Access Point Hinged Cover” section).
The access point can be powered by one of these methods:
– Connecting a 1500 Series Power Injector
– 110 to 240 VAC for a 1552I access point—Connecting Streetlight AC Power
– 110 to 480 VAC for 1552E and 1552EU access points—Connecting Streetlight AC Power
– 120 VAC—Connecting an AC Power Cable to the Access Point
– Connecting a DC Power Cable to the Access Point
– Connecting a Cable POC Power to the Access Point
Note In all cases above, the AC branch circuit powering the access point must be limited to no more than 20A from the over-protection device supplied by the user. This branch power protection must meet all local and national electrical codes.
The power injector provides (AIR-PWRINJ1500-2=) 56 VDC to the access point over the Ethernet cable.
Ensure that the length of the Ethernet cable from the AP to the power injector is more than 10 ft (3 m), but less than 140 ft (42 m). The total length of the cable from the AP to the switch must not exceed 320 ft (100 m).
Note The PoE-Out port is disabled when the access point is powered by the power injector.
Note When not using the AC input connector to power the 1552E or 1552EU (for example when powering using the Cisco power injector), it is important to cover the AC power entry connector. The correct cap is Remke part number 75-0086 (http://www.remke.com/).
When your access point is powered by an optional power injector, follow these steps to complete the installation:
Step 1 Before applying PoE to the access point, ensure that the access point is grounded (see the “Grounding the Access Point” section.
Step 2 Review Figure 2-2 to identify the components needed for the installation.
Note The 1550 power injector can only be used in an indoor environment, therefore, the cable from the injector must travel from the protected location to the outside mounted access point.
Step 3 Connect a CAT5e or better Ethernet cable from your wired LAN network to the power injector.
Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023
Use only the 1500 power injector (AIR-PWRINJ1500-2=) for the access point. This power injector is designed to meet the power requirements of the access point and is a listed Class 2 limited power source (LPS).
Note The installer is responsible for ensuring that powering the access point from this type of power injector is allowed by local and/or national safety and telecommunications equipment standards.
Tip To forward bridge traffic, add a switch between the power injector and controller. Refer to the Cisco Wireless Mesh Access Points, Design and Deployment Guide, Release 7.0 for more information.
Step 4 Ensure that the antennas are connected and that a ground is attached to the access point before you apply power to the access point.
Step 5 Connect a shielded outdoor-rated Ethernet (CAT5e or better) cable between the power injector and the PoE-in connector of the access point (see Figure 2-35).
Step 6 Connect the Ethernet cable to the access point PoE-In port (see “Connecting an Ethernet Cable to the Access Point” section).
Note When a 1552E or1552EU access point is powered by PoE, the PoE-Out port is not active.
Step 7 Continue with What to Do Next.
You need to supply these tools and materials:
Note The PoE-out port is disabled when the access point is powered by the power injector.
To connect the shielded Ethernet cable to the access point, follow these steps:
Step 1 Disconnect power to the power injector, and ensure all power sources to the access point are turned off.
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
Note If your access point contains a backup battery pack, you must press the reset button for 10 seconds or more (see the “Disabling Backup Battery Power” section).
Step 2 Ensure a 6 AWG ground wire is connected to the access point (see the “Grounding the Access Point” section).
Step 3 Use an adjustable wrench, a 22-mm socket, or the Sealcon S-2200-WR wrench to remove the Ethernet connector plug from the access point (see Figure 2-35 for the location).
Figure 2-35 Location of Ethernet Liquid-Tight Adapters (Only Models AIR-CAP1552E-x-K9 and AIR-CAP1552EU-x-K9)
|
|
Note For information on data cable entry, refer to Figure 1-1
Step 4 Loosen the round end of the liquid-tight adapter by turning counterclockwise, but do not remove (see Figure 2-36).
Figure 2-36 liquid-tight Adapter
|
|
Step 5 Insert the unterminated end of the Ethernet cable into the round end of the liquid-tight adapter (see Figure 2-36), and pull several inches of cable through the adapter.
Step 6 Install an RJ-45 connector on the unterminated end of the Ethernet cable using your Ethernet cable installation tool.
Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023
Step 7 Carefully insert the RJ-45 cable connector into the Ethernet port opening on the access point, and connect to the internal Ethernet connector (see Figure 2-37).
Figure 2-37 Inserting RJ-45 Connector into the Ethernet Port Opening in Case
|
|
||
|
|
Step 8 Slide the liquid-tight adapter towards the access point, and screw the threaded end of the adapter into the access point, and hand-tighten.
Step 9 Use an adjustable wrench, a 22-mm socket, or a Sealcon S-2200-WR wrench to tighten the threaded end of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 10 Use an adjustable wrench and tighten the round end of the adapter to 2.7 to 3.2 ft lbs (3.66 to 4.34 Nm).
Step 11 Ensure that the antennas are connected to the access point before you apply power to the access point.
Step 12 Route your Ethernet cable, and cut off any excess cable.
Step 13 Install an RJ-45 connector on the unterminated cable end, and insert it into the power injector. For typical installation components, see Figure 2-2.
Step 14 Turn on power to the power injector.
The Cisco Aironet 1550 series outdoor mesh access point supports these AC power cord options:
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022
Note European Union users need to install a country-specific plug to the blunt cut end of the cable assembly.
Note In all installations, the detachable power cord (pluggable Type B) must be an approved type acceptable to the authorities in the country where the unit is sold, and must meet all local and national electrical codes.
Table 2-4 AC Power Cord Information
When using a user-supplied AC power plug on the AIR-CORD-R3P-40UE= power cord, ensure that the plug is certified for outdoor use and that it has a minimum IP67 rating, such as Interpower 84131251 or Hubbell HBL316P6W (IEC/EN 60309) pin-and-sleeve type connectors. The European Union power cord plug pinouts are listed in Figure 2-38. For the location of the AC power connectors, see Figure 2-40 and Figure 2-41.
Figure 2-38 European Union Plug Pinouts
|
|
|
|
|
|
---|---|---|---|---|---|
When using a strain relief bushing, you should follow these recommendations:
Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046
The access point can be installed on a streetlight pole and powered from a streetlight outdoor light control using the optional streetlight power tap adapter.
When powering the access point with AC power other than the streetlight power tap adapter, you must ensure that the following conditions are observed:
1. AC power can be conveniently removed from the unit. The power should not be removed by disconnecting the AC power connector on the unit.
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
2. You must protect any AC power plugs and AC receptacles from water and other outdoor elements. You can use a UL-listed waterproofing enclosure suitable for covering the AC receptacle and AC power plug that supplies power to the unit as described in Article 406 of the NEC.
3. When you install the access point outdoors or in a wet or damp location, the AC branch circuit that powers the access point should have ground fault protection (GFCI), as required by Article 210 of the National Electrical Code (NEC).
Warning Be very careful when connecting the streetlight adapter to Category 3 pole-top power. If you are not careful, you may electrocute yourself or fall. Statement 363
For additional important safety instructions for AC power cords, refer to the AC Power Cords for Cisco Aironet 1550 Series Outdoor Mesh Access Points document that shipped with your AC power cords.
To install an access point on a streetlight pole, follow these steps:
Step 1 Before beginning the installation, ensure the AC power to the streetlight pole is turned off.
Step 2 Turn off power to the AC power source at the designated circuits.
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
If your access point contains a backup battery pack, you must press the reset button for 10 seconds or more (see the “Disabling Backup Battery Power” section.)
Step 3 When using the streetlight power tap adapter (AIR-PWR-ST-LT-R3P=), ensure that the access point is mounted within 3 feet (1 m) of the outdoor light control. For mounting instructions, refer to the “Installing the Mounting Bracket on a Pole (All Models)” section.
Step 4 Ensure that a 6-AWG ground wire is attached to the access point (see Figure 2-39) and connected to the streetlight pole (for instructions see Grounding the Access Point).
Figure 2-39 Using the Streetlight Power Tap Adapter
|
|
||
|
|
Step 5 Ensure that the streetlight power tap adapter, which uses a 3-pronged LC-10 twist-lock adapter, is placed between the outdoor light control and its fixture (refer to Figure 2-39). The LC-10 twist-lock adapter is designed to be used with LC-10 listed outdoor light controls operating at 100 to 480 VAC, 50 to 60 Hz.
Step 6 Disconnect the outdoor light control from its fixture.
Step 7 Verify that the voltage available at the fixture is between 100 and 480 VAC, 50 to 60 Hz.
Step 8 Turn off power to the fixture at the designated circuits.
Note Ensure that your antennas are connected to the access point before you apply power to the access point.
Step 9 Connect the streetlight power tap adapter to the access point AC power connector, as shown in Figure 2-40 and Figure 2-41. Hand-tighten the connector.
Figure 2-40 AC Power Connector - Shown on Access Point Model AIR-CAP1552E-x-K9
|
Figure 2-41 AC Power Connector - Shown on Access Point Model AIR-CAP1552I-x-K9
|
Step 10 Plug the streetlight power tap adapter into the outdoor light control fixture, as shown in Figure 2-39.
Step 11 Plug the outdoor light control into the streetlight power tap adapter.
Step 12 Ensure that the antennas are connected to the access point before you apply power to the access point.
Step 13 Turn on the power to the outdoor light control fixture at the designated circuits.
When powering the access point with AC power other than the streetlight power tap adapter, you must ensure that the following conditions are observed:
1. AC power can be conveniently removed from the unit. The power should not be removed by disconnecting the AC power connector on the unit.
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
2. You must protect any AC power plugs and AC receptacles from water and other outdoor elements. You can use a UL-listed waterproofing enclosure suitable for covering the AC receptacle and AC power plug that supplies power to the unit as described in Article 406 of the NEC.
3. When you install the access point outdoors or in a wet or damp location, the AC branch circuit that powers the access point should have ground fault protection (GFCI), as required by Article 210 of the National Electrical Code (NEC).
Note For additional important safety instructions for AC power cords, refer to the AC Power Cords for Cisco Aironet 1550 Series Outdoor Mesh Access Points document that shipped with your AC power cords.
The access point supports this Cisco AC power cable:
To connect an AC power cable to the access point, perform these steps:
Step 1 Prior to applying AC power, ensure the access point is grounded (see Grounding the Access Point).
Step 2 Turn off power to the AC power source at the designated circuits.
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
Note If your access point contains a backup battery pack, you must press the reset button for 10 seconds or more (see the “Disabling Backup Battery Power” section).
Step 3 Align the notch in the AC power cable connector with the key in the access point AC power connector, and push the cable connector into the access point connector (see Figure 2-40 or Figure 2-41). When fully seated, rotate the cable connector ring clockwise until hand-tight.
Step 4 Ensure that the antennas are connected to the access point before you apply power to the access point.
Step 5 Turn on the AC power at the designated circuits.
When powering the access point with DC power, you must ensure that DC power can be conveniently removed from the unit. The power should not be removed by disconnecting the DC power connector on the unit.
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
Warning Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV) requirements in IEC 60950 based safety standards. Statement 1033
To connect a DC power cable, you need to supply these tools and material:
To connect the DC power cable to the access point, follow these steps:
Step 1 Before connecting DC power to the access point, ensure that the ground is connected to the access point (see the “Grounding the Access Point” section.
Step 2 Turn off all power sources to the access point, including the DC power source.
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
If your access point contains a backup battery pack, you must press the reset button for 10 seconds or more (see the “Disabling Backup Battery Power” section.)
Step 3 Use an adjustable wrench, a 22-mm socket, or a Sealcon S-2200 -WR wrench to remove the plug in the DC power connector opening (see Figure 2-42 for the location of the DC power connector).
Figure 2-42 Location of the DC Power Liquid-Tight Adapter
|
|
Step 4 Loosen the round end of the liquid-tight adapter by turning counterclockwise, but do not remove (see Figure 2-43).
Figure 2-43 Liquid-Tight Adapter
|
|
Note The liquid-tight adapter accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm).
Step 5 Insert a bare end of the DC power cable into the rounded end of the liquid-tight adapter (see Figure 2-43), and pull approximately 6 inches of cable through the adapter.
Step 6 Strip the DC cable jacket back about 1 inch to expose the wires and strip the insulation about 3/8 inch (9.5 mm) from each wire.
Step 7 Insert each wire into the two-position terminal strip (supplied), and tighten each wire using a 0.1 inch
(0.25 cm) flat screw driver (see Figure 2-44).
Figure 2-44 Two-Position Terminal Strip
|
|
||
|
|
Step 8 Insert the two-position terminal strip into the DC power opening in the access point case, and carefully push the terminal strip into the internal connector (see Figure 2-45).
Figure 2-45 Inserting the Terminal Strip into the DC Power Opening in the Access Point Case
|
|
||
|
|
Step 9 Slide the liquid-tight adapter towards the access point, and screw the threaded end of the adapter into the access point, and hand-tighten.
Step 10 Use an adjustable wrench, a 22-mm socket, or a Sealcon S-2200-WR wrench to tighten the threaded end of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 11 Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs (3.66 to 4.34 Nm).
Step 12 Ensure that the antennas are connected to the access point before you apply power to the access point.
Step 13 Turn on the DC power at the designated circuits.
The cable configuration on a 1552C or 1552CU access point contains a cable modem and RF splitter but does not contain a cable stinger connector. The cable stinger connector is customer supplied.
Note To ensure system performance, with respect to immunity from external electromagnetic fields, the installer must use a well shielded coax cable (quad shield).
Note The POC access point is classified as a type “Hazardous Voltage Secondary” circuit as per the UL/IEC/EN 60950-1 safety standard. The cable distribution network used with this access point must provide transient reduction to the level for this type of circuit classification (that is, 500V transient/lightning surge).
To connect cable POC power to the access point, follow these steps:
Step 1 Before connecting cable POC power to the access point, ensure that the ground is connected to the access point (see the “Grounding the Access Point” section).
Step 2 Ensure that all power sources have been disconnected from the access point.
Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
If your access point contains a backup battery pack, you must press the reset button for 10 seconds or more (see the “Disabling Backup Battery Power” section).
Step 3 Remove the ATTN and SHUNT connector plugs on the top of the access point. Follow your cable company procedures to measure the cable signal strength and possibly adjust signal attenuation externally to the access point or on the RF splitter (see Figure 2-46).
Note The cable modem MAC address is located on the bottom of the access point under the LEDs.
Step 4 Locate the F-connector adapter on the access point (see Figure 2-46).
Figure 2-46 RF Splitter Components
|
|
||
|
|
||
Step 5 Use a Phillips screw driver to loosen the pin capture screw, but be careful not to remove it.
Step 6 Cut the cable stinger connector pin (see Figure 2-47) to 0.75 + 0.1 inch (1.91 + 0.25 cm).
Figure 2-47 Cable Stinger Connector Pin
|
Step 7 Insert the cable stinger connector pin into the cable POC connector opening in the access point case.
Step 8 Screw the F-connector adapter into the POC connector opening, and hand-tighten.
Step 9 Use an adjustable wrench to tighten the F-connector adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 10 Use a Phillips screw driver to tighten the F-connector adapter pin capture screw on the RF splitter to 5.5 to 6.0 in. lbs (0.62 to 0.67 Nm).
Step 11 Before connecting cable POC power to the access point, ensure that the antennas are attached to the access point.
Step 12 Connect or attach the cable company POC cable to the F-connector adapter according to their specifications.
Step 13 Turn on cable POC power.
Step 14 Reinsert the RF splitter shunt.
Step 15 Check the cable modem Power and Cable LEDs and verify that the cable modem receives power and registers to the cable network.
The Power LED (fifth LED from the hinge) is green to indicate power is available.The Cable LED (second LED from the hinge) should be blinking green to indicate scanning the cable network and green to indicate registered on the cable network.
Step 16 Replace the ATTN and SHUNT connector plugs on the top of the access point and tighten to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Before installing your access points, configure your controller by adding the MAC addresses of the access points to the filter list. MAC address filtering is enabled by default. This enables the controller to respond to the listed access points. To add a MAC filter entry on the controller, follow these steps:
Step 1 Log into your controller using a web browser.
Step 2 Choose SECURITY > MAC Filtering > New.
Step 3 Enter the MAC address of the access point to the MAC Filter list; for example, 00:0B:91:21:3A:C7.
Note The access point MAC address is located on the bottom of the unit. When two MAC addresses are shown, use the top MAC address.
Step 4 Select a WLAN ID or Any WLAN from the WLAN ID pop-up menu.
Step 5 Enter a description (32 characters maximum) of the access point in the Description field; for example, Fisher_Street_00.0B.91.21.3A.C7 shows the location and MAC address of the access point.
Step 6 Choose an interface from the Interface Name pop-up menu, and click Apply.
Step 7 Repeat Steps 2 to 6 to add other access points to the list.
Step 8 Log out of your controller, and close your web browser.
The access point defaults to the mesh access point (MAP) radio role. One or more of your access points must be reconfigured as a root access point (RAP). The RAPs connect to a wired Ethernet link through a switch to the controller. The MAPs use their wireless backhaul interface to connect to a RAP to reach the controller.
To configure a RAP on the controller GUI, follow these steps:
Step 1 Log into your controller using a web browser.
Step 2 Click Wireless. When your access point associates to the controller, the name of the access point appears in the AP Name list.
Step 3 Double-click your access point name.
Step 4 Find Mesh Information, and choose Root AP by clicking the drop-down arrow in the AP Role field.
Step 6 Repeat Steps 2 through 5 for each RAP.
Step 7 Log out from your controller, and close your web browser.
The bridge group name (BGN) controls the association of the access points to a RAP. BGNs can be used to logically group the radios to avoid different networks on the same channel from communicating with each other. This setting is also useful if you have more than one RAP in your network in the same area.
If you have two RAPs in your network in the same area (for more capacity), we recommend that you configure the two RAPs with the same BGN, but on different channels.
The BGN is a string of ten characters maximum. A factory-set bridge group name (NULL VALUE) is assigned during manufacturing. It is not visible to you, but allows new access point radios to join a network of new access points. The BGN can be reconfigured from the Controller CLI and GUI. After configuring the BGN, the access point reboots.
The BGN should be configured very carefully on a live network. You should always start from the farthest node (last node) from the RAP and move towards the RAP. If you start configuring the BGN in a different location, then the access points beyond this point (farther away) are dropped, as they have a different BGN.
To configure the BGN for the access points using the GUI, follow these steps:
Step 1 Log into your controller using a web browser.
Step 2 Click Wireless. When access points associates to the controller, the name of the access point appears in the AP Name list.
Step 3 Double-click on an access point name.
Step 4 Find Mesh Information, and enter the new BGN in the Bridge Group Name field.
Step 6 Repeat Steps 2 through 5 for each access point.
Step 7 Log out from your controller, and close your web browser.
When you power up a MAP that is not connected to a wired Ethernet, fiber-optic, or cable network to the controller, the access point uses the Cisco Adaptive Wireless Path Protocol (AWPP) to bind to another mesh access point (MAP) with the best path to a root access point (RAP) connected to the wired network to a controller. The access point sends a discovery request when powered up. If you have configured the access point in the controller correctly, the controller sends back a discovery response to the access point. When that happens, the access point sends out a join request to the controller, and the controller responds with a join confirmation response. Then the access point establishes a Control And Provisioning of Wireless Access Points (CAPWAP) connection to the controller and gets the shared secret configured on the controller.
Refer to the Cisco Wireless LAN Controller Configuration Guide for more information on configuring, monitoring, and operating your access points.